Falco 2

Fixed VOC detector |

The FALCO 2 is offered with or without a built-in pump to meet a wide range of applications and monitoring needs. FALCO 2 includes world-class MiniPID 2 Photoionization (PID).
Sensor in 10.6 eV, 10.0 eV and 11.7 eV variants to allow detection of over 700 volatile organic compounds (VOCs). MiniPID 2 offers additional features such as lamp life and easy service and maintenance.

Falco 2 Falco application

Applications

  • Falco with pump is a fixed VOC gas meter that eliminates false readings found with other competing technologies and continuously monitors volatile organic compounds (VOCs) in hazardous areas.
  • The fixed VOC gas monitor uses a sample line to take samples and is ideal for use in difficult locations such as underground or in confined spaces.
  • Detection range 10.6 eV lamp
    • 10 ppm, 0.001 ppm
    • 50 ppm, 0.01 ppm
    • 1000 ppm, 0.1 ppm
    • 3000 ppm, 1 ppm
  • Detection range 10.0 eV lamp
    • 50 ppm, 0.01 ppm
  • Detection range 11.7 eV lamp
    • 200 ppm, 0.1 ppm

Features and Benefits:

  • Stationary gas meter available with or without pump.
  • Different detection range.
  • Maximum protection
  • Its multi-color LED status display can be seen from a distance of twenty meters in sunlight.
  • Output: 4-20 mA, 2 programmable relays, RS485 Modbus

Specifications

  • Sensor: Detector for photoionization - 10.6 eV, 10.0 eV or 11.7 eV lamp alternative 
  • Reaction time (T90): Pumped models: <10 seconds
  • Protection against ingress: Main unit: IP65, sensor head: IP65
  • Operating voltage: 8 to 40 V DC, Typically 2 W, Max 7 watts
  • Weight & dimensions: 2,5 kg, 223 (h) x 192 (b) x 115 (d) mm
  • Weight & dimensions (with pump): 2,9 kg, 325 (h) x 192 (b) x 115 (d) mm
  • ATEX: II 2G Ex db ib IIC T4 Gb