Gilian 10i – high-flow air sampling pump

Artnr: 910-1501-EU

Gilian 10i is a high-flow air sampling pump from Sensidyne with a flow capacity of approximately 4–10 LPM. It is intended for occupational hygiene and environmental sampling where higher air volumes are required.

Gilian-10i

Features and benefits

  • Higher Flow Applications
    The high flow capability of the Gilian 10i enables sampling capability for applications with flow rates between 4 LPM and 10 LPM.
  • NiMH Memory-Free Battery
    NiMH battery with quick-charge time in under 4 hours. Eliminates shipping and disposal issues.
  • Programmable Functionality
    • Four stage program with repeat cycling
    • Allows scheduled sampling or intermittent duty cycles
    • Programmable delayed start
  • Intuitive Operation with Lock-out Feature
    Simple four-button design makes pump easier to understand and operate.
  • Live Flow Display
    Large display continuously shows real-time flow, total sample time and total volume sampled. Special flow control circuitry automatically compensates for changes in flow rate, backpressure
    and temperature.
  • Intrinsically Safe Certified
    Certified Intrinsically Safe for use in explosive environments.
  • Power Module Accessory
    Continuous run on live power for indefinite length sampling.

Specifications

  • Flow Range: 4.00 – 10.00 LPM
  • Constant Flow Control: ± 5% of set flow at 4-10 LPM
  • Flow Compensation: Up to 5-hours at:
    4 LPM up to 45” H2O back pressure
    5 LPM up to 40” H2O back pressure
    6 LPM up to 34” H2O back pressure
    7 LPM up to 28” H2O back pressure
    8 LPM up to 22” H2O back pressure
    9 LPM up to 18” H2O back pressure
    10 LPM up to 12” H2O back pressure
  • Run Time: 8-hours minimum at:
    4 LPM up to 24” H2O back pressure
    5 LPM up to 20” H2O back pressure
    6 LPM up to 18” H2O back pressure
    7 LPM up to 15” H2O back pressure
    8 LPM up to 12” H2O back pressure
    9 LPM up to 11” H2O back pressure
    10 LPM up to 8” H2O back pressure
  • Flow Fault: If flow changes exceed 5% of set flow within back pressure specifications, fault icon appears. If fault exceeds 30 seconds, pump shuts down. Pump attempts to restart every 3 minutes for up to 30 min.
  • Temperature Ranges: Operating 32°F to 113°F (0°C to 45°C), Storage -4°F to 113°F (-20°C to 45°C), Charging Max 41°F to 104°F (5°C to 40°C)
  • Humidity Ranges: Operating 0-85 %RH, non-condensing, Storage 0-98 %RH, non-condensing
  • Icons: (LCD) Battery Indicator, Hold, Fault, Set
  • Dimensions: 3.2W x 5.4H x 2.3D inches, 8.2W x 13.7H x 5.8D cm
  • Weight: 23 oz. (654 g)
  • Battery Pack: Removable, Sealed, Rechargeable Nickel-Metal-Hydride (6 cells)
  • Battery Level Indicator: Icon displays Full, Mid, & Low levels
  • Charging Time: Under 4 hours
  • Intrinsic Safety: ATEX Ex – II 1 G; Ex ia IIC T4